Auxiliary Siren SW

(DEK, DEK VIP)

HGDefinitionMob.jpg

This feature provides an input for an auxiliary siren On / Off switch for the Siren option.

HGWorkflowNote.jpg

 

Since VIP (Vehicular Interface Port) Inputs are active-low, the auxiliary switch must ground the selected VIP Input to activate the Siren, and idle high to deactivate the Siren. When the DEK or Control Head reports the VIP Input state change (active or inactive) the transceiver sends an SB9600 bus message to the Siren / PA unit to change the Siren state On or Off.

GoArrow.jpg

Go to the DEK VIP Input Feature Selections